Ceph - howto, rbd, lvm, cluster
Install ceph
- Installation depends about which version you want as they're all locked into Fixed releases (argonaut, bobtail etc). So go here for install options for your distro and the version you want:
Video to ceph intro
https://www.youtube.com/watch?v=UXcZ2bnnGZg http://www.youtube.com/watch?v=BBOBHMvKfyc&feature=g-high
Rebooting node stops everything / Set number of replicas across all nodes
Make sure that the min replica count is set to nodes-1.
ceph osd pool set <poolname> min_size 1
Then the remaing node[s] will start up with just 1 node if everything else is down.
Keep in mind this can potentially make stuff ugly as there are no replicas now.
More info here: http://comments.gmane.org/gmane.comp.file-systems.ceph.devel/10481
Add disks (OSD) or entire nodes
Prepare the disk as usual (partition or entire disk) - format with filesystem of choosing. Add to fstab and mount. Add to /etc/ceph/ceph.conf and replicate the new conf to the other nodes.
Start the disk, I'm assuming we've added osd.12 (sdd) on ceph1 here.
## Prepare disk first, create partition and format it <insert parted oneliner> mkfs.xfs -f /dev/sdd1 ## Create the disk ceph osd create [uuid] ## Auth stuff to make sure that the OSD is accepted into the cluser: mkdir /srv/ceph/[uuid_from_above] ceph-osd -i 12 --mkfs --mkkey ceph auth add osd.12 osd 'allow *' mon 'allow rwx' -i /etc/ceph/keyring.osd.12 ## Start it /etc/init.d/ceph start osd.12 ## Add it to the cluster and allow replicated based on CRUSH map. ceph osd crush set 12 osd.12 1.0 pool=default rack=unknownrack host=ceph1-osd
In the line above, if you exchange the pool/rack/host you can place your disk/node where you want.
If you add a new host entry, it will be the same as adding a new node (with the disk).
Check that is in the right place with:
ceph osd tree
More info here:
- http://ceph.com/docs/master/rados/operations/pools/
- http://ceph.com/docs/master/rados/operations/add-or-rm-osds/
Delete pools/OSD
Make sure you have the right disk, run
ceph osd tree
to get an overview.
If OSD is member of a pool and/or active
Here we'll delete osd5
## Mark it out ceph osd out 5 ## Wait for data migration to complete (ceph -w), then stop it service ceph -a stop osd.5 ## Now it is marked out and down
Delete the OSD
## If deleting from active stack, be sure to follow the above to mark it out and down ceph osd crush remove osd.5 ## Remove auth for disk ceph auth del osd.5 ## Remove disk ceph osd rm 5 ## Remove from ceph.conf and copy new conf to all hosts
Add Monitor node/service
Install ceph, add keys, ceph.conf, host files and prepare a storage for containing the maps.
Then add the monitor into the system (To keep quorum, keep either 1 or 3+ - not 2). Examples are adding monitor mon.21 with ip 192.168.0.68
cd /tmp; mkdir add_monitor; cd add_monitor ceph auth get mon. -o key > exported keyring for mon. ceph mon getmap -o map > got latest monmap ceph-mon -i 21 --mkfs --monmap map --keyring key > ceph-mon: created monfs at /srv/ceph/mon21 for mon.21 ceph mon add 21 192.168.0.68 > port defaulted to 6789added mon.21 at 192.168.0.68:6789/0 /etc/init.d/ceph start mon.21
Add the info to the ceph.conf file:
[mon] ... [mon.21] host = ceph2-mon mon addr = 192.168.0.68:6789 ...
Replicating from OSD-based to replication across hosts in a ceph cluster
More info here: http://jcftang.github.com/2012/09/06/going-from-replicating-across-osds-to-replicating-across-hosts-in-a-ceph-cluster/
Replication - see current level pr. OSD
ceph osd dump
CRUSH maps
- Redistributing, [de]assembling and finetuning; more info here:
## save current crushmap in binary ceph osd getcrushmap -o crush.running.map ## Convert to txt crushtool -d crush.running.map -o crush.map ## Edit it and re-convert to binary crushtool -c crush.map -o crush.new.map ## Inject into running system ceph osd setcrushmap -i crush.new.map ## If you've added a new ruleset and want to use that for a pool, do something like: ceph osd pool default crush rule = 4
KVM - add disk
- Substitute <host name='192.168.0.67' port='6789'/> with ip/port of your monitor[s]
- Make sure you have a distinct id for the slotNR: <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/>
- Generate new uuid: uuidgen
- Be sure to have added secret key to libvirt; detailed just below ( http://wiki.skytech.dk/index.php/Ceph_-_howto,_rbd,_lvm,_cluster#KVM_-_add_secret.2Fauth_for_use_with_ceph )
Pr host:
<disk type='network' device='disk'> <driver name='qemu' type='raw'/> <source protocol="rbd" name="test/disk2-qemu-5g:rbd_cache=1"> <host name='192.168.0.67' port='6789'/> <host name='192.168.0.68' port='6789'/> </source> <auth username='admin' type='ceph'> <secret type='ceph' uuid='7a91dc24-b072-43c4-98fb-4b2415322b0f'/> </auth> <target dev='vdb' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </disk>
Pr pool:
<pool type='rbd'> <name>rbd</name> <uuid>f959641f-f518-4505-9e85-17d994e2a399</uuid> <source> <host name='192.168.0.67' port='6789'/> <host name='192.168.0.68' port='6789'/> <host name='192.168.0.69' port='6789'/> <name>test</name> <auth username='admin' type='ceph'> <secret type='ceph' uuid='7a91dc24-b072-43c4-98fb-4b2415322b0f'/> </auth> </source> </pool>
KVM - add secret/auth for use with ceph
Create a secret.xml file:
<secret ephemeral='no' private='no'> <uuid>7a91dc24-b072-43c4-98fb-4b2415322b0f</uuid> <usage type='ceph'> <name>admin</name> </usage> </secret>
Use it:
virsh secret-define secret.xml virsh secret-set-value 7a91dc24-b072-43c4-98fb-4b2415322b0f AQDAD8JQOLS9IxAAbox00eOmlM1h5ZLGPxHGHw==
The last key is the key from your /etc/ceph/keyring.admin
cat /etc/ceph/keyring.admin [client.admin] key = AQDAD8JQOLS9IxAAbox00eOmlM1h5ZLGPxHGHw==
Online resizing of KVM images (rbd)
Resize the desired block-image (here going from 30GB -> 40GB)
qemu-img resize -f rbd rbd:sata/disk3 40G > Image resized.
Find the attached target device:
virsh domblklist rbd-test > Target Source > ------------------------------------------------ > vdb sata/disk2-qemu-5g:rbd_cache=1 > vdc sata/disk3:rbd_cache=1 > hdc -
Then use virsh to tell the guest that the disk has a new size:
virsh blockresize --domain rbd-test --path "vdc" --size 40G > Block device 'vdc' is resized
Check raw rbd info
rbd --pool sata info disk3 > rbd image 'disk3': > size 40960 MB in 10240 objects > order 22 (4096 KB objects) > block_name_prefix: rb.0.13fb.23353e97 > parent: (pool -1)
Make sure you can see the change from dmesg (Guest should see the new size change).
dmesg > [...] > [75830.538557] vdb: detected capacity change from 118111600640 to 123480309760 > [...]
Then extend the partition - if it is a simple data volume, you can just fdisk, remove the old partition, create a new and access default values for start/end (Note, only applies to partitions which holds nothing else!)
ext3/ext4
Write the partition, fdisk -l to doublecheck the size, then remount the partition (the partition from above is mounted as a data dir under vdb1 in my case):
mount -o remount,rw /dev/vdb1
Check your fstab to make sure you get the correct options for the remount.
Afterwards, call the resize2fs:
resize2fs /dev/vdb1 > resize2fs 1.42.5 (29-Jul-2012) > Filesystem at /dev/vdb1 is mounted on /home/mirroruser/mirror; on-line resizing required > old_desc_blocks = 7, new_desc_blocks = 7 > The filesystem on /dev/vdb1 is now 28835584 blocks long.
doublecheck via df -h or the like.
XFS
xfs_growfs /share data blocks changed from 118111600640 to 123480309760
All done
Add/move journal in running cluster
Before starting this, it will be a good idea to make sure the cluster does not automark OSD's out if they've been down for default 300s. You can do that by issuing:
ceph osd set nodown
.. I'll assume we want to update node#1 having OSD 0,1,2 to put a journal on SSD with 10GB. It currently reside on each OSD with a 512MB journal .. .. Assuming we'll be mounting a SSD here: /srv/ceph/journal -- This will then hold all journals as /srv/ceph/journal/osd$id/journal .. # Relevant ceph.conf options .. existing setup .. [osd] osd data = /srv/ceph/osd$id osd journal = /srv/ceph/osd$id/journal osd journal size = 512 # Mark all OSD out (One can do this with an entire node or just a single disk at a time - the latter require a setting under each OSD to locate the journal and not a global OSD option. ceph osd out 0 ceph osd out 1 ceph osd out 2 # Make sure they're marked out ('''ceph osd tree'''), then stop them: /etc/init.d/ceph -a osd.0 stop /etc/init.d/ceph -a osd.1 stop /etc/init.d/ceph -a osd.2 stop # Flush the journal: ceph-osd -i 0 --flush-journal ceph-osd -i 1 --flush-journal ceph-osd -i 2 --flush-journal # Now update ceph.conf - '''this is very important or you'll just recreate journal on the same disk again''' .. change to .. [osd] osd data = /srv/ceph/osd$id osd journal = /srv/ceph/journal/osd$id/journal osd journal size = 10000 # Create new journal on each disk ceph-osd -i 0 --mkjournal ceph-osd -i 1 --mkjournal ceph-osd -i 2 --mkjournal # Done, now start all OSD again /etc/init.d/ceph -a osd.0 start /etc/init.d/ceph -a osd.1 start /etc/init.d/ceph -a osd.2 start # Mark them in again ceph osd in 0 ceph osd in 1 ceph osd in 2
If you set your cluster to not mark OSD's down, remember to remove it!
ceph osd unset nodown
Enjoy your new faster journal!
More info here (source of the above):
Prevent OSD from being marked down
This could be the case while adding new OSD/nodes and some osd keeps being marked down
ceph osd set nodown
Check it is set by issuing:
ceph osd dump | grep flags > flags no-down
When done, remember to unset it or no OSD will ever get marked down!
ceph osd unset nodown
Doublecheck with ceph osd dump | grep flags
OSD optimizations
A few things have helped make my cluster more stable:
Increase osd timeout
I've found the existing 30sec rule is sometimes too little for my 4disk lowend system.
Set the timeout accordingly (try and run debug first to determine if this is really the case).
osd op thread timeout = 60
Adjust transaction commit size
Default value is 300, which is a bit high for highly stressed system/lowcpu
It is adjustable inside the [osd] column:
[osd] ... ## Added new transactional size as default value of 300 is too much osd target transaction size = 50 ...
Change number of disks which can be in recovery
Since my 'cluster' is just 1 machine with 6 osd having multiple recoveries running in parallel will effectively kill it; so I've adjusted it down from the default values:
## Just 2 osd backilling kills a server osd max backfills = 1 osd recovery max active = 1
More info on all the various settings here:
- http://ceph.com/docs/master/rados/configuration/osd-config-ref/#recovery
- http://ceph.com/docs/master/rados/configuration/osd-config-ref/#backfilling
Adjust kernel values
Adjust nr_request in queue (staying in mem - default is 128)
echo 1024 > /sys/block/sdb/queue/nr_requests
Change scheduler as pr. Inktank blogpost:
Full cluster - how to recover
- Add more disks
- Try lower the weight ratio of the full disk
- If everything fails, up the full ratio and immediately change the weight ratio of the disk
ceph pg set_full_ratio 0.98
- If you're really desperate set change the replicate level down
ceph osd pool set <poolname> min_size existing_min_size-1
- Keep in mind this is very dangerous if you hit 1 as min_size; then if any disk fail you'll loose all data!
Alternatively, if you want to change the default values (0.85 as near_full, 0.95 as full), you can add this to the mon section of your ceph.conf:
[mon] ... mon osd nearfull ratio = 0.92 mon osd full ratio = 0.98 ...
Loosing 2 nodes in a 3 node system
Will cause the cluster to halt because of a new feature. Explained by Greg Farnum from Ceph mailinglist:
This took me a bit to work out as well, but you've run afoul of a new post-argonaut feature intended to prevent people from writing with insufficient durability. Pools now have a "min size" and PGs in that pool won't go active if they don't have that many OSDs to write on. The clue here is the "incomplete" state. You can change it with "ceph osd pool foo set min_size 1", where "foo" is the name of the pool whose min_size you wish to change (and this command sets the min size to 1, obviously). The default for new pools is controlled by the "osd pool default min size" config value (which you should put in the global section). By default it'll be half of your default pool size. So in your case your pools have a default size of 3, and the min size is (3/2 = 1.5 rounded up), and the OSDs are refusing to go active because of the dramatically reduced redundancy. You can set the min size down though and they will go active.
Import LVM image into rbd
Do give thought about which version of rbd to use! Format 2 gives additional [great] benefits over format 1
- http://ceph.com/docs/master/man/8/rbd/#parameters
- http://ceph.com/docs/master/man/8/rbd/#commands (check for "This requires format 2")
Turned out to be really simple
I started by grabbing a snapshot of a running lvm
lvcreate -L25G -s -n snap-webserver /dev/storage/webserver
And then just feeding that snapshot directly into rbd:
rbd import /dev/storage/snap-webserver sata/webserver
Here sata/webserver means pool sata. The webserver image will be automatically created.
Create pool with pg_num
It seems to be important to create pools which are big enough in has the number in ^ 2.
So 2048, 4096 etc.
ceph osd pool create sata 4096
Mapping RBD volumes with kernel rbd-fuse client
Mapping volumes
It is recommended to use a 3.6+ kernel for this!
/sbin/modprobe rbd /usr/bin/rbd map --pool sata webserver-data --id admin --keyring /etc/ceph/keyring.admin
Then it will show up as device /etc/rbd[X]
Then you can format it, partition it or do what you want - and then mount it like a normal device.
Unmapping volumes
If you want to remove a mapping for a device, issue:
## First unmount from system, then: rbd unmap /dev/rbd[X]
Flashcache
- http://www.sebastien-han.fr/blog/2012/11/15/make-your-rbd-fly-with-flashcache/
- Options about how to use/mount the flashcache ( https://github.com/facebook/flashcache/blob/master/doc/flashcache-sa-guide.txt )
- Writethrough - safest, all writes are cached to ssd but also written to disk immediately. If your ssd has slower write performance than your disk (likely for early generation SSDs purchased in 2008-2010), this may limit your system write performance. All disk reads are cached (tunable).
- Writearound - again, very safe, writes are not written to ssd but directly to disk. Disk blocks will only be cached after they are read. All disk reads are cached (tunable).
- Writeback - fastest but less safe. Writes only go to the ssd initially, and based on various policies are written to disk later. All disk reads are cached (tunable).
Various stuff
Inflight IO
- You can peek at in-flight IO (and other state) with
cat /sys/kernel/debug/ceph/*/osdc
- Ask via socket admin call
- ceph --admin-daemon /var/run/ceph/ceph-osd.NN.asok dump_ops_in_flight
NFS over rbd (with pacemaker in 2x setup)
Backup VM's using rbd (req. format 2)
Bring down a server/rack/whatever for maint and stop ceph from redistributing data
Source: http://ceph.com/docs/master/rados/operations/troubleshooting-osd/#stopping-w-out-rebalancing
## Set cluster to now mark OSD down ceph osd set noout ## Once the cluster is set to nodown, you can begin stopping the OSDs within the failure domain that requires maintenance work. ceph osd stop osd.{num} ## Note Placement groups within the OSDs you stop will become degraded while you are addressing issues with within the failure domain. ## Once you have completed your maintenance, restart the OSDs. ceph osd start osd.{num} ## Finally, you must unset the cluster from nodown. ceph osd unset noout
RBD
Using rbd
Creating a 50GB share in sata named rpmbuilder-ceph could be done like:
rbd create sata/rpmbuilder-ceph --size 51200
also qemu-img can create rbd images; I fancy it works the same, but am not entirely sure.
Using KVM
qemu-img create -f rbd rbd:sata/rpmbuilder-ceph 50G